Tiivistelmä
By increased and widespread usage of wearable monitoring devices a huge volume of data is generated which requires various automated methods for analyzing and processing them and also extracting useful information from them. Since it is almost impossible for physicians and nurses to monitor physical activities of their patients for a long time, there is a need for automated data analysis techniques that abstract the information and highlight the significant events for clinicians and healthcare experts.
The main objective of this thesis work was towards an automatic digital signal processing approach from physiological signal classification to processing and analyzing the two most vital physiological signals in long-term healthcare monitoring (ECG and IP). At the first stage, an automated generic physiological signal classifier for detecting an unknown recorded signal was introduced and then different algorithms for processing and analyzing the ECG and IP signals were developed and evaluated. This master thesis was a part of DISSE project which its aim was to design a new health-care system with the aim of providing medical expertise more accessible, affordable, and convenient. In this work, different publicly available databases such as MIT-BIH arrhythmia and CEBS were used in the development and evaluation phases.
The proposed novel generic physiological signal classifier has the ability to distinguish five types of physiological signals (ECG, Resp, SCG, EMG and PPG) from each other with 100 % accuracy. Although the proposed classifier was not very successful in distinguishing lead I and II of ECG signal from each other (error of 27% was reported) which means that the general purpose features were enough discriminating to recognize different physiological signals from each other but not enough for classifying different ECG leads.
For ECG processing and analysis section, three QRS detection methods were implemented which modified Pan-Tompkins gave the best performance with 97% sensitivity and 96,45% precision. The morphological based ectopic detection method resulted in sensitivity of 85,74% and specificity of 84,34%. Furthermore, for the first PVC detection algorithm (sum of trough) the optimal threshold and range were studied according to the AUC of ROC plot which the highest sensitivity and specificity were obtained with threshold of −5 and range of 11 : 25 that were equal to 87% and 82%, respectively. For the second PVC detection method (R-peak with minimum) the best performance was achieved with threshold of −0.7 that resulted in sensitivity of 68% and specificity of 72%. In the IP analysis section, an ACF approach was implemented for respiratory rate estimation. The estimated respira- tion rate obtained from IP signal and oronasal mask were compared and the total MAE and RMSE errors were computed that were equal to 0.40 cpm and 1.20 cpm, respectively. The implemented signal processing techniques and algorithms can be tested and improved with measured data from wearable devices for ambulatory applications.
The main objective of this thesis work was towards an automatic digital signal processing approach from physiological signal classification to processing and analyzing the two most vital physiological signals in long-term healthcare monitoring (ECG and IP). At the first stage, an automated generic physiological signal classifier for detecting an unknown recorded signal was introduced and then different algorithms for processing and analyzing the ECG and IP signals were developed and evaluated. This master thesis was a part of DISSE project which its aim was to design a new health-care system with the aim of providing medical expertise more accessible, affordable, and convenient. In this work, different publicly available databases such as MIT-BIH arrhythmia and CEBS were used in the development and evaluation phases.
The proposed novel generic physiological signal classifier has the ability to distinguish five types of physiological signals (ECG, Resp, SCG, EMG and PPG) from each other with 100 % accuracy. Although the proposed classifier was not very successful in distinguishing lead I and II of ECG signal from each other (error of 27% was reported) which means that the general purpose features were enough discriminating to recognize different physiological signals from each other but not enough for classifying different ECG leads.
For ECG processing and analysis section, three QRS detection methods were implemented which modified Pan-Tompkins gave the best performance with 97% sensitivity and 96,45% precision. The morphological based ectopic detection method resulted in sensitivity of 85,74% and specificity of 84,34%. Furthermore, for the first PVC detection algorithm (sum of trough) the optimal threshold and range were studied according to the AUC of ROC plot which the highest sensitivity and specificity were obtained with threshold of −5 and range of 11 : 25 that were equal to 87% and 82%, respectively. For the second PVC detection method (R-peak with minimum) the best performance was achieved with threshold of −0.7 that resulted in sensitivity of 68% and specificity of 72%. In the IP analysis section, an ACF approach was implemented for respiratory rate estimation. The estimated respira- tion rate obtained from IP signal and oronasal mask were compared and the total MAE and RMSE errors were computed that were equal to 0.40 cpm and 1.20 cpm, respectively. The implemented signal processing techniques and algorithms can be tested and improved with measured data from wearable devices for ambulatory applications.