Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Time-domain optical coherence tomography at 2 µm using GaSb-based broadband superluminescent diode

Alam Bhuiyan, Ifte Khairul; Jiménez, Alejandro Martínez; Cernat, Ramona; Uceda, Adrián Fernández; Hilska, Joonas; Peil, Markus; Marques, Manuel Jorge; Dobre, George; Viheriälä, Jukka; Podoleanu, Adrian; Guina, Mircea (2026-05-18)

 
Avaa tiedosto
Time-domain_optical_coherence_tomography_at_2_m_using_GaSb-based_broadband_superluminescent_diode.pdf (3.272Mt)
Lataukset: 



Alam Bhuiyan, Ifte Khairul
Jiménez, Alejandro Martínez
Cernat, Ramona
Uceda, Adrián Fernández
Hilska, Joonas
Peil, Markus
Marques, Manuel Jorge
Dobre, George
Viheriälä, Jukka
Podoleanu, Adrian
Guina, Mircea
18.05.2026

Optics Express
doi:10.1364/OE.592137
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202607018081

Kuvaus

Peer reviewed
Tiivistelmä
We report a time-domain optical coherence tomography (TD-OCT) system operating in the 2 µm spectral region, enabled by a GaSb-based superluminescent diode (SLD). The spectrum emitted by the SLD exhibits a full-width half-maximum (FWHM) of ∼80 nm centered near 2.1 µm. For OCT operation, stable amplified spontaneous emission with low spectral ripple (<20%) is maintained at drive currents below 150 mA. The SLD is fiber coupled and integrated into a fiber-based Michelson interferometer. In the OCT system, the measured coherence envelope yields an axial resolution of approximately 300 µm in air and enables depth-resolved imaging of scattering paint-based coating samples. In contrast to OCT implementations at 2 µm wavelength region that commonly rely on supercontinuum sources, the use of GaSb-based SLDs offers a compact, practical alternative, leveraging the maturity and scalability of electrically driven semiconductor light sources packaged in a standard “butterfly” module. This report represents the first demonstration of TD-OCT imaging at 2 µm using a GaSb-based SLD source and establishes its suitability for compact and scalable mid-IR OCT instrumentation targeting non-biological, low-water-content materials.
Kokoelmat
  • TUNICRIS-julkaisut [24991]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste