Padé Approximant Neural Networks for Enhanced Electric Motor Fault Diagnosis Using Vibration and Acoustic Data

Kilickaya, Sertac; Eren, Levent (2025-10)

 
Avaa tiedosto
Pad_Approximant_Neural_Networks_for_Enhanced_Electric_Motor_Fault_Diagnosis_Using_Vibration_and_Acoustic_Data.pdf (3.090Mt)
Lataukset: 



Kilickaya, Sertac
Eren, Levent
10 / 2025

Journal of Vibration Engineering and Technologies
539
This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1007/s42417-025-02129-5
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202603303587

Kuvaus

Peer reviewed
Tiivistelmä
Purpose: The primary aim of this study is to enhance fault diagnosis in induction machines by leveraging the Padé Approximant Neuron (PAON) model. While accelerometers and microphones are standard in motor condition monitoring, deep learning models with nonlinear neuron architectures offer promising improvements in diagnostic performance. This research investigates whether Padé Approximant Neural Networks (PadéNets) can outperform conventional Convolutional Neural Networks (CNNs) and Self-Organized Operational Neural Networks (Self-ONNs) in the diagnosis of electrical and mechanical faults from vibration and acoustic data. Methods: We evaluate and compare the diagnostic capabilities of three deep learning architectures: one-dimensional CNNs, Self-ONNs, and PadéNets. These models are tested on the University of Ottawa’s publicly available constant-speed induction motor datasets, which include both vibration and acoustic sensor data. The PadéNet model is designed to introduce enhanced nonlinearity and is compatible with unbounded activation functions such as LeakyReLU. Results and Conclusion: PadéNets consistently outperformed the baseline models, achieving diagnostic accuracies of 99.96%, 98.26%, 97.61%, and 98.33% for accelerometers 1, 2, 3, and the acoustic sensor, respectively. The enhanced nonlinearity of PadéNets, together with their compatibility with unbounded activation functions, significantly improves fault diagnosis performance in induction motor condition monitoring.
Kokoelmat
  • TUNICRIS-julkaisut [24323]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste