Use of ST/HR hysteresis decreases false positive rate in exercise electrocardiography test of middle-aged asymptomatic women

Enroth, Miro; Sievänen, Harri; Asikainen, Tuikku Tuula Maria Agnes; Viik, Jari (2024-11-01)

 
Avaa tiedosto
Use_of_ST_HR_hysteresis_decreases_false_positive_rate.pdf (599.8Kt)
Lataukset: 



Enroth, Miro
Sievänen, Harri
Asikainen, Tuikku Tuula Maria Agnes
Viik, Jari
01.11.2024

Journal of Electrocardiology
153820
doi:10.1016/j.jelectrocard.2024.153820
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202602192637

Kuvaus

Peer reviewed
Tiivistelmä
Background: Exercise electrocardiography (ECG) is a common diagnostic and prognostic method for the detection of coronary artery disease (CAD). However, its accuracy in asymptomatic women has not been comprehensively investigated and the diagnostic criteria may require refinements. This study evaluated the performance of ECG-derived ST/HR-index, ST/HR hysteresis and ST-segment depression parameters among asymptomatic middle-aged women. Methods: 108 women (mean age 56 ± 4 years) performed exercise ECG test on treadmill until exhaustion three times within a nine-month period. False-positive rates of maximum ST/HR-index, ST/HR hysteresis, and ST-segment depression values measured from 12 leads at peak exercise and after one-minute recovery were evaluated with recommended diagnostic partition values. Repeatability was assessed with intraclass correlation (ICC) and Bland-Altman plot analysis. Results: False-positive rate was lower for all variables when a two‑lead configuration was used instead of a single‑lead configuration. Using a two‑lead configuration, ST/HR hysteresis (0–1.9 %) and ST-segment depression after one-minute recovery (0–2.8 %) had lower false-positive rates compared to ST/HR index (3.7–20.4 %) and ST-segment depression at peak exercise (9.3–27.8 %). ICC values indicated moderate repeatability for ST/HR hysteresis while ST/HR index, ST-segment at peak exercise, and ST-segment after one-minute recovery had moderate-to-good repeatability. Bland-Altman analysis indicated poor repeatability for all evaluated ECG variables. Conclusion: In asymptomatic middle-aged women, practitioners should prefer the use of ST/HR hysteresis and ST-segment after one-minute recovery over the conventional ST-segment depression at peak exercise or ST/HR index, and evaluate the ECG data from a two‑lead configuration instead of single‑lead.
Kokoelmat
  • TUNICRIS-julkaisut [25008]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste