Radiation Exposure during Elective Endovascular Abdominal Aortic Aneurysm Repair: A Nationwide Study of Patient Doses in Finland

Laurén, Jouni; Kaasalainen, Touko; Kesävuori, Risto; Nikulainen, Veikko; Suominen, Velipekka; Hakulinen, Ullamari; Karjalainen, Jari; Kariniemi, Juho; Venermo, Maarit; Aho, Pekka (2025-12-01)

 
Avaa tiedosto
Radiation_Exposure_during_Elective_Endovascular_Abdominal_Aortic_Aneurysm_Repair_A_Nationwide_Study_of_Patient_Doses_in_Finland.pdf (422.4Kt)
Lataukset: 



Laurén, Jouni
Kaasalainen, Touko
Kesävuori, Risto
Nikulainen, Veikko
Suominen, Velipekka
Hakulinen, Ullamari
Karjalainen, Jari
Kariniemi, Juho
Venermo, Maarit
Aho, Pekka
01.12.2025

European Journal of Vascular and Endovascular Surgery
doi:10.1016/j.ejvs.2025.11.058
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202602122458

Kuvaus

Peer reviewed
Tiivistelmä
OBJECTIVE: Endovascular aneurysm repair (EVAR) predisposes patients to significant radiation exposure, with well known harmful effects. This study aimed to assess the radiation doses and their consistency in Finland and to investigate the factors affecting the doses, to potentially allow future dose reductions.METHODS: This retrospective, nationwide, multicentre study included all patients who underwent an elective standard EVAR procedure in Finland between 2017 - 2022. Data were collected from: body mass index (BMI); fluoroscopy time (FT); radiation exposure, including kerma area product (KAP) and cumulative air kerma at the patient reference entrance point (Ka,r) from fluoroscopy and digital subtraction angiography (DSA); number of DSA series; and exposure parameters of the angiography systems. Descriptive statistics and linear regression analyses were performed to identify the parameters that significantly influenced radiation exposure.RESULTS: A total of 1 185 EVAR procedures from all five centres that perform EVAR in Finland were included in the study. Large variation in medians of total procedure KAP between the centres was observed, ranging 22.5 - 135.0 Gy·cm2. Median FT ranged 16.1 - 29.1 minutes. Both fluoroscopy and DSA showed large variation in radiation exposure. BMI did not significantly differ between the centres. The factors significantly affecting the dose in the multivariate linear regression model were BMI, FT, number of DSA acquisitions, DSA frame rate, and maximum copper filtration in fluoroscopy.CONCLUSION: Surprisingly high, up to six fold, intercentre variability in total procedure radiation exposure was observed. The variability in the doses was mostly attributable to differences in exposure parameters (e.g., dose at detector level, copper filtration, and pulse rate); the manner in which radiation is utilised also played a significant role. In other words, both angiography system parameters and the working habits of the operator need to be optimised.
Kokoelmat
  • TUNICRIS-julkaisut [24447]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste