Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Threshold estimation in running using dynamical correlations of RR intervals

Kanniainen, Matias; Laatikainen-Raussi, Vesa; Pukkila, Teemu; Vohlakari, Krista; Hynynen, Esa; Ihalainen, Johanna K.; Räsänen, Esa (2025-05)

 
Avaa tiedosto
Physiological_Reports_-_2025_-_Kanniainen_-_Threshold_estimation_in_running_using_dynamical_correlations_of_RR_intervals.pdf (1.723Mt)
Lataukset: 



Kanniainen, Matias
Laatikainen-Raussi, Vesa
Pukkila, Teemu
Vohlakari, Krista
Hynynen, Esa
Ihalainen, Johanna K.
Räsänen, Esa
05 / 2025

Physiological Reports
e70241
doi:10.14814/phy2.70241
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202508048011

Kuvaus

Peer reviewed
Tiivistelmä
We study the estimation of aerobic threshold (AeT) and anaerobic threshold (AnT) using dynamical detrended fluctuation analysis (DDFA). Conventionally, the thresholds are estimated in laboratory settings, where the subject performs an incremental exercise test on a cycloergometer or treadmill. We compared DDFA-based thresholds (DDFAT1 and DDFAT2) with lactate thresholds (LT1 and LT2) and examined thresholds derived from theoretical and measured maximal heart rates (HR). The analysis was conducted on 58 subjects undergoing an incremental treadmill running test. Our findings indicate significant discrepancies between thresholds derived from theoretical and measured maximal HRs compared to lactate thresholds. Specifically, theoretical maximal HR thresholds consistently underestimated lactate thresholds, exhibiting systematic bias. Measured maximal HR thresholds also showed a consistent underestimation, though with improved alignment to lactate thresholds. In contrast, the DDFA-based method demonstrated reasonable agreement with lactate thresholds and lacked systematic bias. The DDFA-based approach offers a simple and accurate alternative for estimating AeT and AnT. Its potential for continuous monitoring makes it suitable for integration into wearable devices such as smartwatches and heart rate monitors.
Kokoelmat
  • TUNICRIS-julkaisut [24199]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste