Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Ambient-Pressure Multischeme Chemical Ionization for Pesticide Detection: A MION-Orbitrap Mass Spectrometry Study

Partovi, Fariba; Mikkilä, Joona; Iyer, Siddharth; Mikkilä, Jyri; Kontro, Jussi; Ojanperä, Suvi; Shcherbinin, Aleksei; Rissanen, Matti (2025-06-03)

 
Avaa tiedosto
partovi-et-al-2025-ambient-pressure-multischeme-chemical-ionization-for-pesticide-detection-a-mion-orbitrap-mass.pdf (3.747Mt)
Lataukset: 



Partovi, Fariba
Mikkilä, Joona
Iyer, Siddharth
Mikkilä, Jyri
Kontro, Jussi
Ojanperä, Suvi
Shcherbinin, Aleksei
Rissanen, Matti
03.06.2025

ACS Omega
doi:10.1021/acsomega.4c11287
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202508017992

Kuvaus

Peer reviewed
Tiivistelmä
This study explores pesticide detection with diverse ionization reagents by employing Multischeme chemical IONization inlet (MION) in conjunction with high-resolution Orbitrap mass spectrometry (MS). Various ionization schemes, specifically charging by Br- and O2- in negative polarity, and by H3O+ and C3H6OH+ in positive polarity, were investigated. The findings build on our previous work concerning pesticide detection using multischeme ionization and further demonstrate the effectiveness of the MION-MS methodology for detecting pesticides from complex standard mixtures and fruit extracts. The method successfully detected 136 compounds at a concentration of 10 ng/mL, and 447 at a concentration of 100 ng/mL, from standard solutions containing altogether 651 pesticides. The analysis of 10 fruit extracts revealed detections comparable to those obtained with validated methods. Subsequent molecular modeling provided insight into product identities observed when using protonated acetone as a reagent ion, which revealed that fragmentation into protonated pesticide and neutral acetone is energetically favored over decomposition to pesticide and protonated acetone (reactants). The current study amply underscores the versatility of the MION-MS methodology in seamlessly transitioning between different reagent ions in both polarities, enabling detection of a wider range of chemical compounds than with any single-ion-scheme instrument.
Kokoelmat
  • TUNICRIS-julkaisut [25224]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste