Particle number concentrations in office spaces around Europe
Salo, Laura; Silvonen, Ville; Raunima, Tuomas; Vojtisek-Lom, Michal; Ondracek, Jakub; Topinka, Jan; Schins, Roel P.F.; Lepistö, Teemu; Lintusaari, Henna; Saarikoski, Sanna; Barreira, Luis M.F.; Hoivala, Jussi; Markkula, Lassi; Kulmala, Ilpo; Vinha, Juha; Karjalainen, Panu; Rönkkö, Topi (2024)
Salo, Laura
Silvonen, Ville
Raunima, Tuomas
Vojtisek-Lom, Michal
Ondracek, Jakub
Topinka, Jan
Schins, Roel P.F.
Lepistö, Teemu
Lintusaari, Henna
Saarikoski, Sanna
Barreira, Luis M.F.
Hoivala, Jussi
Markkula, Lassi
Kulmala, Ilpo
Vinha, Juha
Karjalainen, Panu
Rönkkö, Topi
2024
This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202507247757
https://urn.fi/URN:NBN:fi:tuni-202507247757
Kuvaus
Peer reviewed
Tiivistelmä
In this work, we investigated indoor air particle number concentrations and their size distributions in four office spaces in Europe. We used an Electrical low-pressure impactor (ELPI+) to enable high time-resolution, as well as a wide size range of particles (here 16 nm to 1 µm). In addition to indoor air concentrations, we report the concurrent outdoor concentrations and their relationship to one another. Infiltration factors ranged from 0.22 to 0.6 and the contribution of indoor sources was from 6 % to 51 %. Mechanically ventilated buildings had less infiltration. The number concentrations in two offices were always above the “low” threshold value given by the World Health Organization.