Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

New approach methods for assessing indoor air toxicity

Mannerström, Marika; Dvorakova, Marketa; Svobodova, Lada; Rucki, Marian; Kotal, Filip; Vavrouš, Adam; Vrbíková, Věra; Kejlova, Kristina; Jirova, Dagmar; Heinonen, Tuula (2022)

 
Avaa tiedosto
1_s2.0_S2666027X22000275_main.pdf (4.036Mt)
Lataukset: 



Mannerström, Marika
Dvorakova, Marketa
Svobodova, Lada
Rucki, Marian
Kotal, Filip
Vavrouš, Adam
Vrbíková, Věra
Kejlova, Kristina
Jirova, Dagmar
Heinonen, Tuula
2022

Current research in toxicology
100090
doi:10.1016/j.crtox.2022.100090
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202301271805

Kuvaus

Peer reviewed
Tiivistelmä
<p>Indoor air is typically a mixture of many chemicals at low concentrations without any adverse health effects alone, but in mixtures they may cause toxicity and risks to human health. The aim of this study was by using new approach methods to assess the potential toxicity of indoor air condensates. In specific, different in vitro test methods including cyto-and immunotoxicity, skin sensitization and endocrine disruption were applied. In addition to biological effects, the indoor air samples were subjected to targeted analysis of 25 volatile organic compounds (VOCs) and Genapol X-80 (a nonionic emulsifier) suspected to be present in the samples, and to a non-targeted "total chemical scan" to find out whether the chemical composition of the samples is associated with the biological effects. The results confirm that assessing health risks of indoor air by analysing individual chemicals is not an adequate approach: We were not able to detect the VOCs and Genapol X-80 in the indoor air samples, yet, several types of toxicity, namely, cytotoxicity, immunotoxicity, skin sensitization and endocrine disruption were detected. In the non-targeted total chemical scan of the indoor air samples, a larger number of compounds were found in the cytotoxic samples than in the non-cytotoxic samples supporting the biological findings. If only one biological method would be selected for the screening of indoor air quality, THP-1 macrophage/WST-1 assay would best fit for the purpose as it is sensitive and serves as a good representative for different sub-toxic end points, including immunotoxicity, (skin) sensitization and endocrine disruption.</p>
Kokoelmat
  • TUNICRIS-julkaisut [26236]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste