Extending the Range of Detectable Trace Species with the Fast Polarity Switching of Chemical Ionization Orbitrap Mass Spectrometry

Cai, Runlong; Mikkilä, Joona; Bengs, Anna; Koirala, Mrisha; Mikkilä, Jyri; Holm, Sebastian; Juuti, Paxton; Meder, Melissa; Partovi, Fariba; Shcherbinin, Aleksei; Worsnop, Douglas; Ehn, Mikael; Kangasluoma, Juha (2024-05-28)

 
Avaa tiedosto
Extending_the_Range_of_Detectable_Trace_Species_with_the_Fast_Polarity_Switching_of_Chemical_Ionization_Orbitrap_Mass_Spectrometry.pdf (3.106Mt)
Lataukset: 



Cai, Runlong
Mikkilä, Joona
Bengs, Anna
Koirala, Mrisha
Mikkilä, Jyri
Holm, Sebastian
Juuti, Paxton
Meder, Melissa
Partovi, Fariba
Shcherbinin, Aleksei
Worsnop, Douglas
Ehn, Mikael
Kangasluoma, Juha
28.05.2024

Analytical Chemistry
doi:10.1021/acs.analchem.4c00650
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202503102637

Kuvaus

Peer reviewed
Tiivistelmä
<p>Chemical ionization (CI) atmospheric pressure interface mass spectrometry is a unique analytical technique for its low detection limits, softness to preserve molecular information, and selectivity for particular classes of species. Here, we present a fast polarity switching approach for highly sensitive online analysis of a wide range of trace species in complex samples using selective CI chemistries and high-resolution mass spectrometry. It is achieved by successfully coupling a multischeme chemical ionization inlet (MION) and an Orbitrap Fourier transform mass spectrometer. The capability to flexibly combine ionization chemistries from both polarities effectively extends the detectability compared to using only one ionization chemistry, as commonly used positive and negative reagent ions tend to be sensitive to different classes of species. We tested the performance of the MION-Orbitrap using reactive gaseous organic species generated by α-pinene ozonolysis in an environmental chamber and a standard mixture of 71 pesticides. Diethylammonium and nitrate are used as reagent ions in positive and negative polarities. We show that with a mass resolving power of 280,000, the MION-Orbitrap can switch and measure both polarities within 1 min, which is sufficiently fast and stable to follow the temporal evolution of reactive organic species and the thermal desorption profile of pesticides. We detected 23 of the 71 pesticides in the mixture using only nitrate as the reagent ion. Facilitated by polarity switching, we also detected 47 pesticides using diethylammonium, improving the total number of detected species to 59. For reactive organic species generated by α-pinene ozonolysis, we show that combining diethylammonium and nitrate addresses the need to measure oxygenated molecules in atmospheric environments with a wide range of oxidation states. These results indicate that the polarity switching MION-Orbitrap can promisingly serve as a versatile tool for the nontargeted chemical analysis of trace species in various applications.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20689]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste