Spinal cord fMRI with MB-SWIFT for assessing epidural spinal cord stimulation in rats

Laakso, Hanne; Lehto, Lauri J.; Paasonen, Jaakko; Salo, Raimo; Canna, Antonietta; Lavrov, Igor; Michaeli, Shalom; Gröhn, Olli; Mangia, Silvia (2021-05-18)

 
Avaa tiedosto
spinal_cord_fMRI_2021.pdf (915.7Kt)
Lataukset: 



Laakso, Hanne
Lehto, Lauri J.
Paasonen, Jaakko
Salo, Raimo
Canna, Antonietta
Lavrov, Igor
Michaeli, Shalom
Gröhn, Olli
Mangia, Silvia
18.05.2021

Magnetic Resonance in Medicine
doi:10.1002/mrm.28844
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202106085764

Kuvaus

Peer reviewed
Tiivistelmä
<p>Purpose: Electrical epidural spinal cord stimulation (SCS) is used as a treatment for chronic pain as well as to partially restore motor function after a spinal cord injury. Monitoring the spinal cord activity during SCS with fMRI could provide important and objective measures of integrative responses to treatment. Unfortunately, spinal cord fMRI is severely challenged by motion and susceptibility artifacts induced by the implanted electrode and bones. This pilot study introduces multi-band sweep imaging with Fourier transformation (MB-SWIFT) technique for spinal cord fMRI during SCS in rats. Given the close to zero acquisition delay and high bandwidth in 3 dimensions, MB-SWIFT is demonstrated to be highly tolerant to motion and susceptibility-induced artifacts and thus holds promise for fMRI during SCS. Methods: MB-SWIFT with 0.78 × 0.78 × 1.50 mm<sup>3</sup> spatial resolution and 3-s temporal resolution was used at 9.4 Tesla in rats undergoing epidural SCS at different frequencies. Its performance was compared with spin echo EPI. The origin of the functional contrast was also explored using suppression bands. Results: MB-SWIFT was tolerant to electrode-induced artifacts and respiratory motion, leading to substantially higher fMRI sensitivity than spin echo fMRI. Clear stimulation frequency-dependent responses to SCS were detected in the rat spinal cord close to the stimulation site. The origin of MB-SWIFT fMRI signals was consistent with dominant inflow effects. Conclusion: fMRI of the rat spinal cord during SCS can be consistently achieved with MB-SWIFT, thus providing a valuable experimental framework for assessing the effects of SCS on the central nervous system.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20247]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste