Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Early ischemic ST-segment and T-wave changes during balloon angioplasty

Pessah, Mazal Anna; Huhtala, Heini; Kosonen, Petteri; Eskola, Markku; Pérez-Riera, Andrés Ricardo; Nikus, Kjell; Rankinen, Jani (2022)

 
Avaa tiedosto
1_s2.0_S0022073622000838_main.pdf (3.628Mt)
Lataukset: 



Pessah, Mazal Anna
Huhtala, Heini
Kosonen, Petteri
Eskola, Markku
Pérez-Riera, Andrés Ricardo
Nikus, Kjell
Rankinen, Jani
2022

Journal of Electrocardiology
doi:10.1016/j.jelectrocard.2022.06.003
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202207045962

Kuvaus

Peer reviewed
Tiivistelmä
<p>Background: Acute coronary occlusion results in increased T-wave amplitude and ST-segment elevation in the ECG leads facing the ischemic region. Material and methods: We performed continuous ECG recording in 34 patients during balloon occlusion of the left anterior descending (LAD), left circumflex (LCx) and right coronary artery (RCA). Delta (Δ) ST and ΔT amplitudes were calculated by subtracting the preinflation values from the values measured during balloon inflation. Results: Occlusion of the LAD resulted in greater increase in the amplitude of the T wave than of the ST segment in lead V2 (ΔT +3.4 mm, inter-quartile range [IQR] 1—6 mm; ΔST +1.4 mm, 0.5—3 mm). During RCA occlusion, ΔST and ΔT didn't differ significantly. LCx occlusion resulted in significant differences between ΔST and ΔT in all leads, except aVF and V3-V4. In two patients (LCx), we observed a biphasic ST-T response: an initial negative change of the T-wave amplitude was followed by a positive change in leads V1-V2. In leads II, III, aVF and V4-V6, there was an initial positive change, followed by a final negative change towards the end of the occlusion. Conclusion: Continuous 12‑lead ECG recording during balloon occlusion of the LCx resulted in significant differences between the ΔST and ΔT values in all leads except aVF and V3-V4. LAD and RCA occlusion resulted in less evident differences between the ST-segment and T-wave changes. A change in polarity of T-wave changes during balloon occlusion (initial negative and final positive change, or vice versa) proved to be a rare finding.</p>
Kokoelmat
  • TUNICRIS-julkaisut [22385]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste