The consistency and reliability of six-strand and four-strand flexor tendon repairs: a comparative porcine cadaveric study

Kuronen, Jaakko A. E.; Riski, Benjamin; Leppänen, Olli V.; Karjalainen, Teemu; Linnanmäki, Lasse (2022-01)

 
Avaa tiedosto
JHSE_D_21_00490_R4_4.pdf (1.049Mt)
Lataukset: 



Kuronen, Jaakko A. E.
Riski, Benjamin
Leppänen, Olli V.
Karjalainen, Teemu
Linnanmäki, Lasse
01 / 2022

Journal of Hand Surgery: European Volume
This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1177/17531934211066556
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202208176470

Kuvaus

Peer reviewed
Tiivistelmä
<p>The aim of this study was to compare the consistency and reliability of the six-strand Gan modification of the Lim-Tsai flexor tendon repair with the four-strand Adelaide repair, both with 3-0 sutures and with eight to ten runs of simple 5-0 running peripheral suture as well as the influence of the surgeons’ level of experience on the strength of the repair in a cadaveric animal setup. Thirty-nine surgeons repaired 78 porcine flexor digitorum profundus tendons with either the Adelaide technique (39 tendons) or the modified Lim-Tsai technique (39 tendons). Each repaired tendon was tested in a material testing machine under a single cycle load-to-failure test. The forces were recorded when the gap between the two tendon stumps reached 1 and 2 mm and when irreversible elongation or total rupture occurred. We found no significant differences in gap formation force and yielding strength of the tendons between the two methods. The surgeon’s previous experience in tendon repairs did not improve the consistency, reliability or tensile strength of the repairs. We conclude that if a strong peripheral suture is added, the modified Lim-Tsai repair has the same technical reliability and consistency as the Adelaide repair in term of ultimate loading strength in this test setup.</p>
Kokoelmat
  • TUNICRIS-julkaisut [22960]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste