Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Validity and Reliability of the Integrated Palliative Care Outcome Scale in Asian Heart Failure Patients

Neo, Shirlyn Hui-Shan; Tan, Jasmine Yun-Ting; Sim, David Kheng-Leng; Ng, Elaine Swee-Ling; Loh, Julian Kenrick Xingyuan; Yang, Grace Meijuan; Murtagh, Fliss E M; Cheung, Yin Bun (2022)

 
Avaa tiedosto
pmr.2022.0029.pdf (530.9Kt)
Lataukset: 



Neo, Shirlyn Hui-Shan
Tan, Jasmine Yun-Ting
Sim, David Kheng-Leng
Ng, Elaine Swee-Ling
Loh, Julian Kenrick Xingyuan
Yang, Grace Meijuan
Murtagh, Fliss E M
Cheung, Yin Bun
2022

Palliative Medicine Reports
doi:10.1089/pmr.2022.0029
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202302032028

Kuvaus

Peer reviewed
Tiivistelmä
BACKGROUND: The Integrated Palliative Care Outcome Scale (IPOS) was developed in the United Kingdom for health assessment in advanced illness.OBJECTIVES: To evaluate the validity and reliability of a culturally adapted IPOS (both patient and staff versions) for heart failure (HF).DESIGN/SETTING: We recruited HF patients and staff from a tertiary hospital in Singapore. We collected patient IPOS, New York Heart Association (NYHA) status, Edmonton Symptom Assessment System (ESAS) and Minnesota Living with Heart Failure (MLHF) scores at baseline, and patient IPOS at follow-up. Each baseline patient IPOS was matched with a staff IPOS.MEASUREMENTS: Pearson correlation coefficient (r) between ESAS, MLHF, and patient IPOS was calculated to assess construct validity. The two-sample T-test assessed difference in patient and staff IPOS scores across NYHA status and care settings for known-group validity. Internal consistency of patient and staff IPOS was assessed using Cronbach's alpha (α). Intraclass correlation coefficient (ICC) was used to assess test-retest reliability of patient IPOS and inter-rater reliability between patient and staff IPOS.RESULTS: Ninety-one patients and 12 staff participated. There was strong convergent validity of total patient IPOS with MLHF (r = 0.78) and ESAS (r = 0.81). There were statistically significant differences in total IPOS across care settings (patient-IPOS: 8.05, staff-IPOS 13.61) and NYHA (patient-IPOS: 7.52, staff-IPOS 12.71).There was high internal consistency of total patient (α = 0.83) and staff IPOS (α = 0.88) and high test-retest reliability of patient IPOS (ICC 0.81). Inter-rater reliability (ICC) ranged between 0.82 and 0.91.CONCLUSION: The IPOS was valid and reliable for HF patients in Singapore.
Kokoelmat
  • TUNICRIS-julkaisut [25675]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste