Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of deep learning segmentation and multigrader-annotated mandibular canals of multicenter CBCT scans

Järnstedt, Jorma; Sahlsten, Jaakko; Jaskari, Joel; Kaski, Kimmo; Mehtonen, Helena; Lin, Ziyuan; Hietanen, Ari; Sundqvist, Osku; Varjonen, Vesa; Mattila, Vesa; Prapayasotok, Sangsom; Nalampang, Sakarat (2022-11)

 
Avaa tiedosto
s41598_022_20605_w.pdf (2.797Mt)
Lataukset: 



Järnstedt, Jorma
Sahlsten, Jaakko
Jaskari, Joel
Kaski, Kimmo
Mehtonen, Helena
Lin, Ziyuan
Hietanen, Ari
Sundqvist, Osku
Varjonen, Vesa
Mattila, Vesa
Prapayasotok, Sangsom
Nalampang, Sakarat
11 / 2022

Scientific Reports
18598
doi:10.1038/s41598-022-20605-w
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202212099005

Kuvaus

Peer reviewed
Tiivistelmä
Deep learning approach has been demonstrated to automatically segment the bilateral mandibular canals from CBCT scans, yet systematic studies of its clinical and technical validation are scarce. To validate the mandibular canal localization accuracy of a deep learning system (DLS) we trained it with 982 CBCT scans and evaluated using 150 scans of five scanners from clinical workflow patients of European and Southeast Asian Institutes, annotated by four radiologists. The interobserver variability was compared to the variability between the DLS and the radiologists. In addition, the generalisation of DLS to CBCT scans from scanners not used in the training data was examined to evaluate its out-of-distribution performance. The DLS had a statistically significant difference (p < 0.001) with lower variability to the radiologists with 0.74 mm than the interobserver variability of 0.77 mm and generalised to new devices with 0.63 mm, 0.67 mm and 0.87 mm (p < 0.001). For the radiologists’ consensus segmentation, used as a gold standard, the DLS showed a symmetric mean curve distance of 0.39 mm, which was statistically significantly different (p < 0.001) compared to those of the individual radiologists with values of 0.62 mm, 0.55 mm, 0.47 mm, and 0.42 mm. These results show promise towards integration of DLS into clinical workflow to reduce time-consuming and labour-intensive manual tasks in implantology.
Kokoelmat
  • TUNICRIS-julkaisut [24385]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste