CIB W040: International surveys considering moisture safety in buildings during design and construction

Morishita-Steffen, N.; Laukkarinen, A.; Lewis, T.; Wolny, S.; Peuhkuri, R.; Vinha, J.; Bednar, T. (2021-12-02)

 
Avaa tiedosto
Morishita_Steffen_2021_J._Phys._Conf._Ser._2069_012042.pdf (813.6Kt)
Lataukset: 



Morishita-Steffen, N.
Laukkarinen, A.
Lewis, T.
Wolny, S.
Peuhkuri, R.
Vinha, J.
Bednar, T.
02.12.2021

012042
doi:10.1088/1742-6596/2069/1/012042
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202201031031

Kuvaus

Peer reviewed
Tiivistelmä
<p>We conducted comparative surveys of design consultants in three countries to determine current knowledge and experienced moisture problems. The study is part of the CIB W040 research roadmap needs analyses for realigning research efforts with stakeholder requirements for moisture safety. Survey results show that a third of construction projects in the last five years were affected by moisture problems, even though practitioners applied multiple preventative measures at least some of the time. Water installations caused approximately 20 % of the moisture damage. In each country, preventing moisture damage was necessary; the means to address problems varied, with no one dominating solution. Design and construction guidelines were more helpful than the building code requirements. Information is available, but designers need dedicated time and budget for implementing better moisture safety. A quantitative goal is to increase the frequency of moisture safety measures while increasing the availability of tools. The usefulness of selected measures and instruments is strongly case-specific. Subtopic analysis such as causes of moisture damage due to leaky water installations needs more detailed investigation. Further research is needed building upon the online survey results to develop intelligent tools preventing moisture damage in the design, construction, and building occupancy phases.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20711]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste