Left Ventricular Wall Motion Estimation by Active Polynomials for Acute Myocardial Infarction Detection

Kiranyaz, Serkan; Degerli, Aysen; Hamid, Tahir; Mazhar, Rashid; Ahmed, Rayyan El Fadil; Abouhasera, Rayaan; Zabihi, Morteza; Malik, Junaid; Hamila, Ridha; Gabbouj, Moncef (2020-11-17)

 
Avaa tiedosto
09261387.pdf (2.748Mt)
Lataukset: 



Kiranyaz, Serkan
Degerli, Aysen
Hamid, Tahir
Mazhar, Rashid
Ahmed, Rayyan El Fadil
Abouhasera, Rayaan
Zabihi, Morteza
Malik, Junaid
Hamila, Ridha
Gabbouj, Moncef
17.11.2020

IEEE Access
doi:10.1109/ACCESS.2020.3038743
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202012309206

Kuvaus

Peer reviewed
Tiivistelmä
Echocardiogram (echo) is the earliest and the primary tool for identifying regional wall motion abnormalities (RWMA) in order to diagnose myocardial infarction (MI) or commonly known as heart attack. This paper proposes a novel approach, Active Polynomials , which can accurately and robustly estimate the global motion of the Left Ventricular (LV) wall from any echo in a robust and accurate way. The proposed algorithm quantifies the true wall motion occurring in LV wall segments so as to assist cardiologists diagnose early signs of an acute MI. It further enables medical experts to gain an enhanced visualization capability of echo images through color-coded segments along with their “maximum motion displacement” plots helping them to better assess wall motion and LV Ejection-Fraction (LVEF). The outputs of the method can further help echo-technicians to assess and improve the quality of the echocardiogram recording. A major contribution of this study is the first public echo database collection composed by physicians at the Hamad Medical Corporation Hospital in Qatar. The so-called HMC-QU database will serve as the benchmark for the forthcoming relevant studies. The results over HMC-QU dataset show that the proposed approach can achieve 87.94% accuracy, 92.86% sensitivity and 87.64% precision in MI detection even though the echo quality is quite poor and the temporal resolution is low.
Kokoelmat
  • TUNICRIS-julkaisut [24199]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste