The detection and stability of the SARS-CoV-2 RNA biomarkers in wastewater influent in Helsinki, Finland

Hokajärvi, Anna Maria; Rytkönen, Annastiina; Tiwari, Ananda; Kauppinen, Ari; Oikarinen, Sami; Lehto, Kirsi Maarit; Kankaanpää, Aino; Gunnar, Teemu; Al-Hello, Haider; Blomqvist, Soile; Miettinen, Ilkka T.; Savolainen-Kopra, Carita; Pitkänen, Tarja (2021)

 
Avaa tiedosto
the_detection_and_stability_2021.pdf (674.0Kt)
Lataukset: 



Hokajärvi, Anna Maria
Rytkönen, Annastiina
Tiwari, Ananda
Kauppinen, Ari
Oikarinen, Sami
Lehto, Kirsi Maarit
Kankaanpää, Aino
Gunnar, Teemu
Al-Hello, Haider
Blomqvist, Soile
Miettinen, Ilkka T.
Savolainen-Kopra, Carita
Pitkänen, Tarja
2021

Science of the Total Environment
145274
doi:10.1016/j.scitotenv.2021.145274
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202104284061

Kuvaus

Peer reviewed
Tiivistelmä
<p>Wastewater-based surveillance of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is used to monitor the population-level prevalence of the COVID-19 disease. In many cases, due to lockdowns or analytical delays, the analysis of wastewater samples might only be possible after prolonged storage. In this study, the effect of storage conditions on the RNA copy numbers of the SARS-CoV-2 virus in wastewater influent was studied and compared to the persistence of norovirus over time at 4 °C, −20 °C, and −75 °C using the reverse-transcription quantitative PCR (RT-qPCR) assays E-Sarbeco, N2, and norovirus GII. For the first time in Finland, the presence of SARS-CoV-2 RNA was tested in 24 h composite influent wastewater samples collected from Viikinmäki wastewater treatment plant, Helsinki, Finland. The detected and quantified SARS-CoV-2 RNA copy numbers of the wastewater sample aliquots taken during 19–20 April 2020 and stored for 29, 64, and 84 days remained surprisingly stable. In the stored samples, the SARS betacoronavirus and SARS-CoV-2 copy numbers, but not the norovirus GII copy numbers, seemed slightly higher when analyzed from the pre-centrifuged pellet—that is, the particulate matter of the influent—as compared with the supernatant (i.e., water fraction) used for ultrafiltration, although the difference was not statistically significant. Furthermore, when wastewater was spiked with SARS-CoV-2, linear decay at 4 °C was observed on the first 28 days, while no decay was visible within 58 days at −20 °C or −75 °C. In conclusion, freezing temperatures should be used for storage when immediate SARS-CoV-2 RNA analysis from the wastewater influent is not possible. Analysis of the particulate matter of the sample, in addition to the water fraction, can improve the detection frequency.</p>
Kokoelmat
  • TUNICRIS-julkaisut [22385]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste