Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

X-ray microtomography is a novel method for accurate evaluation of small-bowel mucosal morphology and surface area

Virta, Johannes; Hannula, Markus; Tamminen, Ilmari; Lindfors, Katri; Kaukinen, Katri; Popp, Alina; Taavela, Juha; Saavalainen, Päivi; Hiltunen, Pauliina; Hyttinen, Jari; Kurppa, Kalle (2020)

 
Avaa tiedosto
X_ray_microtomography_is_a_novel_method_2020.pdf (2.200Mt)
Lataukset: 



Virta, Johannes
Hannula, Markus
Tamminen, Ilmari
Lindfors, Katri
Kaukinen, Katri
Popp, Alina
Taavela, Juha
Saavalainen, Päivi
Hiltunen, Pauliina
Hyttinen, Jari
Kurppa, Kalle
2020

Scientific reports
13164
doi:10.1038/s41598-020-69487-w
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/urn:nbn:fi:tuni-202009167023

Kuvaus

Peer reviewed
Tiivistelmä
<p>The often poorly orientated small-bowel mucosal biopsies taken for the diagnostics of celiac disease and other intestinal disorders are prone to misinterpretation. Furthermore, conventional histopathology has suboptimal sensitivity for early histopathological changes observed in short-term challenge studies. X-ray microtomography (micro-CT) is a promising new method for accurate imaging of human-derived biological samples. Here, we report that micro-CT could be utilized to create virtual reconstructions of endoscopically obtained intestinal biopsies. The formed digital 3D images enabled selection of always optimal cutting angles for accurate measurement of the mucosal damage and revealed diagnostic lesions in cases interpreted as normal with conventional histomorphometry. We also demonstrate that computer-assisted point cloud analysis can be used to calculate biologically meaningful surface areas of the biopsies in different stages of mucosal damage with excellent replicability and correlation with other disease parameters. We expect the improved diagnostic accuracy and capability to measure the surface areas to provide a powerful tool for the diagnostics of intestinal diseases and for future clinical and pharmaceutical trials.</p>
Kokoelmat
  • TUNICRIS-julkaisut [25354]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste