Assessment of MRI-based Attenuation Correction for MRI-only Radiotherapy Treatment Planning of the Brain

Ranta, Iiro; Teuho, Jarmo; Linden, Jani; Klén, Riku; Teräs, Mika; Kapanen, Mika; Keyriläinen, Jani (2020-05-14)

 
Avaa tiedosto
diagnostics_10_00299.pdf (1.592Mt)
Lataukset: 



Ranta, Iiro
Teuho, Jarmo
Linden, Jani
Klén, Riku
Teräs, Mika
Kapanen, Mika
Keyriläinen, Jani
14.05.2020

Diagnostics
doi:10.3390/diagnostics10050299
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202202222096

Kuvaus

Peer reviewed
Tiivistelmä
<p>Magnetic resonance imaging-only radiotherapy treatment planning (MRI-only RTP) and positron emission tomography (PET)-MRI imaging require generation of synthetic computed tomography (sCT) images from MRI images. In this study, initial dosimetric evaluation was performed for a previously developed MRI-based attenuation correction (MRAC) method for use in MRI-only RTP of the brain. MRAC-based sCT images were retrospectively generated from Dixon MR images of 20 patients who had previously received external beam radiation therapy (EBRT). Bone segmentation performance and Dice similarity coefficient of the sCT conversion method were evaluated for bone volumes on CT images. Dose calculation accuracy was assessed by recalculating the CT-based EBRT plans using the sCT images as the base attenuation data. Dose comparison was done for the sCT- and CT-based EBRT plans in planning target volume (PTV) and organs at risk (OAR). Parametric dose comparison showed mean relative differences of <0.4% for PTV and <1.0% for OARs. Mean gamma index pass rates of 95.7% with the 2%/2 mm agreement criterion and 96.5% with the 1%/1 mm agreement criterion were determined for glioma and metastasis patients, respectively. Based on the results, MRI-only RTP using sCT images generated from MRAC images can be a feasible alternative for radiotherapy of the brain.</p>
Kokoelmat
  • TUNICRIS-julkaisut [22109]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste