Ballistocardiography can Estimate Beat-to-Beat Heart Rate Accurately at Night in Patients after Vascular Intervention

Antink, Christoph Hoog; Mai, Yen; Aalto, Roosa; Brüser, Christoph; Vehkaoja, Antti; Leonhardt, Steffen; Oksala, Niku (2020)

 
Avaa tiedosto
Ballistocardiography_can_Estimate_Beat_to_Beat_Heart_Rate_Accurately_at_Night_in_Patients_after_Vascular_Intervention_post_print.pdf (3.039Mt)
Lataukset: 



Antink, Christoph Hoog
Mai, Yen
Aalto, Roosa
Brüser, Christoph
Vehkaoja, Antti
Leonhardt, Steffen
Oksala, Niku
2020

IEEE Journal of Biomedical and Health Informatics
This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1109/jbhi.2020.2970298
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202008266694

Kuvaus

Peer reviewed
Tiivistelmä
While bed-integrated ballistocardiography (BCG) has potential clinical applications such as unobtrusive monitoring of patients staying in the general hospital ward, it has so far mainly gained interest in the wellness domain. In this article, the potential of BCG to monitor hospitalized patients after surgical intervention was assessed. Long-term BCG recordings (mean duration 17.7 h) of 14 patients were performed with an EMFit QS bed sensor. In addition, ten healthy subjects were recorded during sleep (mean duration 7.8 h). Using an iterative algorithm, beat-to-beat intervals (BBIs) and the ultra-short-term heart-rate-variability (HRV) parameters standard deviation of NN intervals (SDNN) and root mean square of successive differences (RMSSD) were estimated and compared to an ECG reference in terms of average estimation error and temporal coverage. While the absolute BBI estimation error was found to be higher when full-day patient data was used (16.5 ms), no significant difference between healthy subjects (12.7 ms) and patient nighttime data (11.0 ms) was observed. Nevertheless, temporal coverage of BBI estimation was significantly lower in patients (39.3% overall, 51.7% at night) compared to the healthy sleepers (73.2%). This resulted in reduced HRV estimation coverage (9.7% vs. 37.2%) at comparable estimation error levels.
Kokoelmat
  • TUNICRIS-julkaisut [25310]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste