Impact force excitation generated by an ISO tapping machine on wooden floors

Lietzén, Jesse; Miettinen, Juha; Kylliäinen, Mikko; Pajunen, Sami (2020-04)

 
Avaa tiedosto
1_s2.0_S0003682X20309269_main.pdf (1.665Mt)
Lataukset: 



Lietzén, Jesse
Miettinen, Juha
Kylliäinen, Mikko
Pajunen, Sami
04 / 2020

Applied Acoustics
107821
doi:10.1016/j.apacoust.2020.107821
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202101181445

Kuvaus

Peer reviewed
Tiivistelmä
<p>Prediction of the impact sound insulation of wooden floors requires information of the excitation forces driving the structure. According to earlier research, it is evident, that the impact force generated by the ISO tapping machine on the wooden floors is different than on bare concrete floors. However, only a few measurement results of the force have been shown in the literature. The purpose of our study was to experimentally determine the impact force excitation with an instrumented ISO tapping machine on a large range of wooden floors. One of the hammers of the tapping machine was equipped with both force and acceleration sensors. The hammer itself was modified to fulfil the requirements for the tapping machine presented in the standards ISO 10140-5 and ISO 16283-2. Based on the measured force signals, force spectra and impulses exerted by the instrumented hammer were determined. According to the results, differences between the force spectra on the wooden floors were prominent in the frequencies above 500 Hz. In the low-frequency range, the variation of the driving force corresponded to a level difference of more than 3 dB. In addition, the results showed that the process of excitation was not transient for the structures studied. Thus, the vibration of the measured wooden floors did not seem to influence the impact force. The findings of this paper are of very high importance for those developing mathematical calculation tools to predict the impact sound insulation of wooden floors.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20127]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste