Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Safety at chimney-roof penetration: A numerical investigation

Neri, Manuela; Perttu, Leppänen; Alanen, Mika; Luscietti, Davide; Pilotelli, Mariagrazia (2020)

 
Avaa tiedosto
Safety_at_Chimney_Roof_Penetration_2020.pdf (1.481Mt)
Lataukset: 



Neri, Manuela
Perttu, Leppänen
Alanen, Mika
Luscietti, Davide
Pilotelli, Mariagrazia
2020

Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202009237098

Kuvaus

Peer reviewed
Tiivistelmä
<p>Chimneys convey exhaust gas produced in heat generators to the external ambient. To do this, they cross building elements such as floors and roofs, which can be made of flammable materials such as wood, wood fiber, cellulose, etc. This represents a dangerous condition that can lead to the overheating of the structure and, consequently, to possible fires. In recent years, numerous roof fires have occurred in Europe due to the presence of a chimney, and some of these have also involved certified chimneys. The aim of the certification procedure is the determination of the distance between chimney and flammable structures to avoid fires. This paper describes an investigation performed to understand the causes of the high number of fires and to propose solutions to the roof fires problem. The study was carried out numerically and experimentally, and consisted of three steps. Firstly, the chimney certification procedure was investigated to highlight possible weaknesses. Then, by means of a 2D and a 3D numerical models, the variables affecting heat transfer at chimney-roof penetration were identified. Finally, solutions and prescriptions to prevent roof fires are proposed. The solutions consist of a set of tables for checking chimney installations, and a universal device to be installed between chimney and roof to prevent the overheating of the latter, also in very critical conditions represented by soot fires, and installations in very thick and insulating roofs.</p>
Kokoelmat
  • TUNICRIS-julkaisut [22461]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste