Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Ectopic Beat Detection from Wrist Optical Signals for Sinus Rhythm and Atrial Fibrillation Subjects

Haddad, Serj; Harju, Jarkko; Tarniceriu, Adrian; Halkola, Tuomas; Parak, Jakub; Korhonen, Ilkka; Yli-Hankala, Arvi; Vehkaoja, Antti (2019)

 
Avaa tiedosto
Ectopic_Beat_Detection_from_Wrist_Optical_Signals_for_Sinus_Rhythm_and_Atrial_Fibrillation_Subjects.pdf (426.0Kt)
Lataukset: 



Haddad, Serj
Harju, Jarkko
Tarniceriu, Adrian
Halkola, Tuomas
Parak, Jakub
Korhonen, Ilkka
Yli-Hankala, Arvi
Vehkaoja, Antti
2019

This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1007/978-3-030-31635-8_18
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202103052390

Kuvaus

Peer reviewed
Tiivistelmä
<p>Ectopic beats are abnormal cardiac beats originating from a location different than the sino-atrial node and therefore not being controlled by the autonomous nervous system. Thus, correct heart rate variability analysis inevitably requires accurate ectopic beat detection. Furthermore, an accurate ectopic beat detection is crucial to differentiate irregular cardiac rhythm due to different types of pathological arrhythmias from those caused by isolated ectopic beats. In this paper, we present an algorithm for ectopic beat detection based on wrist plethysmographic (PPG) signals. The proposed algorithm relies on analyzing the inter-beat patterns while considering the heart-rhythm condition: whether sinus rhythm (SR) or atrial fibrillation (AF). We monitor 29 patients recovering from surgery in the post-anesthesia care unit. During the recordings, 15 patients had SR and 14 patients had AF. The proposed ectopic beat detection algorithm achieves a sensitivity of and a specificity of 2.12.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20709]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste