On the Performance of Bed-Integrated Ballistocardiography in Long-Term Heart Rate Monitoring of Vascular Patients

Antink, Christoph Hoog; Mai, Yen; Ranta, Jukka; Tamiceriu, Adrian; Brüser, Christoph; Leonhardt, Steffen; Oksala, Niku; Vehkaoja, Antti (2019)

 
Avaa tiedosto
on_the_performance_of_bed_integrated_2019.pdf (1.012Mt)
Lataukset: 



Antink, Christoph Hoog
Mai, Yen
Ranta, Jukka
Tamiceriu, Adrian
Brüser, Christoph
Leonhardt, Steffen
Oksala, Niku
Vehkaoja, Antti
2019

167
doi:10.22489/CinC.2019.167
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202103052393

Kuvaus

Peer reviewed
Tiivistelmä
<p>The application of ballistocardiography (BCG) for unobtrusive monitor of (beat-to-beat) heart rate in sleeping subjects has seen increased attention in recent years. While most studies are performed on healthy volunteers, some studies have included subjects with sleep-related problems. Even so, little attention has been payed to patients suffering from cardiovascular diseases. In addition, most studies are either limited to short laboratory measurements or overnight recordings of sleeping subjects.In this work, we present preliminary results on beat-to-beat interval estimation of long-term (> 21 h) BCG recordings in a hospital environment. Measurements were obtained from five subjects after peripheral vascular surgery or endovascular interventions and compared to Holter recordings. The commercially available sensor Emfit QS as well an augmented version of the CLIE interval estimation algorithm were used. Using the proposed approach, an average relative beat-to-beat interval error of 3.8 % at a coverage of 61.5 % was achieved. Error and coverage were found to vary from subject to subject as well as time of day. On average, findings are comparable though inferior to results reported on insomniac subjects in a sleep laboratory environment.</p>
Kokoelmat
  • TUNICRIS-julkaisut [24173]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste