Online Scent Classification by Ion-Mobility Spectrometry Sequences

Müller, Philipp; Salminen, Katri; Kontunen, Anton; Karjalainen, Markus; Isokoski, Poika; Rantala, Jussi; Leivo, Joni; Väliaho, Jari; Kallio, Pasi; Lekkala, Jukka; Surakkka, Veikko (2019)

 
Avaa tiedosto
fams_05_00039.pdf (1.802Mt)
Lataukset: 



Müller, Philipp
Salminen, Katri
Kontunen, Anton
Karjalainen, Markus
Isokoski, Poika
Rantala, Jussi
Leivo, Joni
Väliaho, Jari
Kallio, Pasi
Lekkala, Jukka
Surakkka, Veikko
2019

Frontiers in Applied Mathematics and Statistics
39
doi:10.3389/fams.2019.00039
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/urn:nbn:fi:tty-201909022047

Kuvaus

Peer reviewed
Tiivistelmä
For ion-mobility spectrometry (IMS)-based electronic noses (eNose) samples of scents are markedly time-dependent, with a transient phase and a highly volatile stable phase in certain conditions. At the same time, the samples depend on various environmental factors, such as temperature and humidity. This makes fast classification of scents challenging. The present aim was to develop and test an algorithm for online scent classification that mitigates these dependencies by using both baseline measurements and sequences of samples for classification. A classifier based on the K nearest neighbors approach was derived. The classifier is able to use measurements from both transient and stable phase, yields a label for the analyzed scent, and information on the trustworthiness of the returned label. In order to avoid the classifier being fooled by irrelevant features and to reduce the dimensionality of the feature space, principal component analysis was applied to the data. The classifier was tested with four food scents, each presented in two different ways to the IMS. By using baseline measurements, the misclassification rate was reduced from 20.0 to 13.3%. A second experiment showed that the used IMS type experiences device heterogeneity.
Kokoelmat
  • TUNICRIS-julkaisut [24324]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste