Gas-phase endstation of electron, ion and coincidence spectroscopies for diluted samples at the FinEstBeAMS beamline of the MAX IV 1.5 GeV storage ring

Kooser, Kuno; Kivimäki, Antti; Turunen, Paavo; Pärna, Rainer; Reisberg, Liis; Kirm, Marco; Valden, Mika; Huttula, Marko; Kukk, Edwin (2020-07-01)

 
Avaa tiedosto
Gas_phase_endstation_of_electron_2020.pdf (1.333Mt)
Lataukset: 



Kooser, Kuno
Kivimäki, Antti
Turunen, Paavo
Pärna, Rainer
Reisberg, Liis
Kirm, Marco
Valden, Mika
Huttula, Marko
Kukk, Edwin
01.07.2020

JOURNAL OF SYNCHROTRON RADIATION
doi:10.1107/S1600577520007146
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202008316783

Kuvaus

Peer reviewed
Tiivistelmä
<p>Since spring 2019 an experimental setup consisting of an electron spectrometer and an ion time-of-flight mass spectrometer for diluted samples has been available for users at the FinEstBeAMS beamline of the MAX IV Laboratory in Lund, Sweden. The setup enables users to study the interaction of atoms, molecules, (molecular) microclusters and nanoparticles with short-wavelength (vacuum ultraviolet and X-ray) synchrotron radiation and to follow the electron and nuclear dynamics induced by this interaction. Test measurements of N2 and thiophene (C4H4S) molecules have demonstrated that the setup can be used for many-particle coincidence spectroscopy. The measurements of the Ar 3p photoelectron spectra by linear horizontal and vertical polarization show that angle-resolved experiments can also be performed. The possibility to compare the electron spectroscopic results of diluted samples with solid targets in the case of Co2O3 and Fe2O3 at the Co and Fe L 2,3-absorption edges in the same experimental session is also demonstrated. Because the photon energy range of the FinEstBeAMS beamline extends from 4.4 eV up to 1000 eV, electron, ion and coincidence spectroscopy studies can be executed in a very broad photon energy range.</p>
Kokoelmat
  • TUNICRIS-julkaisut [24742]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste