Evaluation of printed P(VDF-TrFE) pressure sensor signal quality in arterial pulse wave measurement

Laurila, Mika-Matti; Peltokangas, Mikko; Lozano Montero, Karem; Siponkoski, Tuomo; Juuti, Jari; Tuukkanen, Sampo; Oksala, Niku; Vehkaoja, Antti; Mäntysalo, Matti (2019)

 
Avaa tiedosto
08796416.pdf (5.992Mt)
Lataukset: 



Laurila, Mika-Matti
Peltokangas, Mikko
Lozano Montero, Karem
Siponkoski, Tuomo
Juuti, Jari
Tuukkanen, Sampo
Oksala, Niku
Vehkaoja, Antti
Mäntysalo, Matti
2019

IEEE Sensors Journal
This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1109/jsen.2019.2934943
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/urn:nbn:fi:tuni-201909273556

Kuvaus

Peer reviewed
Tiivistelmä
In this contribution, we evaluate the performance of an additively fabricated piezoelectric poly(vinylidenefluoride-cotrifluoroethylene) (P(VDF-TrFE)) based dynamic pressure sensor in non-invasive arterial pulse wave (PW) measurement. Additively fabricated piezoelectric sensors have high potential for the realization of affordable and unobtrusive PW measurement systems which could enable the long-term monitoring of patients with cardiovascular diseases (CVDs). However, the accuracy and reliability of such sensors have not been extensively studied before. We propose an additive fabrication process for a P(VDF-TrFE) PW-sensor, measure PW from the radial artery at the wrist from 22 healthy volunteer subjects, calculate clinically relevant parameters based on the PW waveform and compare their values to the values obtained from concurrent measurement with an electromechanical film (EMFi) based reference sensor, used earlier in several clinical studies. We show that the signals recorded with the two sensors, as well as the radial augmentation index (rAIx) and the stiffness index (SI) calculated from them, are in good agreement with each other. These results demonstrate that the additively fabricated P(VDF-TrFE) PW sensors can reach a suitable level of accuracy and reliability for clinical use.
Kokoelmat
  • TUNICRIS-julkaisut [25020]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste