Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Super-resolution microscopy for biological specimens: Lensless phase retrieval in noisy conditions

Shevkunov, Igor; Katkovnik, Vladimir; Petrov, Nikolay V.; Egiazarian, Karen (2018-11-01)

 
Avaa tiedosto
boe_9_11_5511_1.pdf (2.397Mt)
Lataukset: 



Shevkunov, Igor
Katkovnik, Vladimir
Petrov, Nikolay V.
Egiazarian, Karen
01.11.2018

Biomedical Optics Express
#340805
This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1364/BOE.9.005511
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-201910224008

Kuvaus

Peer reviewed
Tiivistelmä
<p>The paper is devoted to a computational super-resolution microscopy. A complex-valued wavefront of a transparent biological cellular specimen is restored from multiple intensity diffraction patterns registered with noise. For this problem, the recently developed lensless super-resolution phase retrieval algorithm [Optica, 4(7), 786 (2017)] is modified and tuned. This algorithm is based on a random phase coding of the wavefront and on a sparse complex-domain approximation of the specimen. It is demonstrated in experiments, that the reliable phase and amplitude imaging of the specimen is achieved for the low signal-to-noise ratio provided a low dynamic range of observations. The filterings in the observation domain and specimen variables are specific features of the applied algorithm. If these filterings are omitted the algorithm becomes a super-resolution version of the standard iterative phase retrieval algorithms. In comparison with this simplified algorithm with no filterings, our algorithm shows a valuable improvement in imaging with much smaller number of observations and shorter exposure time. In this way, presented algorithm demonstrates ability to work in a low radiation photon-limited mode.</p>
Kokoelmat
  • TUNICRIS-julkaisut [23470]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste