Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Atrial Fibrillation Detection from Wrist Photoplethysmography Data Using Artificial Neural Networks

Rezaei Yousefi, Zeinab; Parak, Jakub; Tarniceriu, Adrian; Harju, Jarkko; Yli-Hankala, Arvi; Korhonen, Ilkka; Vehkaoja, Antti (2018)

 
Avaa tiedosto
Atrial_Fibrillation_Detection_from_Wrist_Photoplethysmography_Data_Using_Artificial_Neural_Networks_post_print.pdf (1.376Mt)
Lataukset: 



Rezaei Yousefi, Zeinab
Parak, Jakub
Tarniceriu, Adrian
Harju, Jarkko
Yli-Hankala, Arvi
Korhonen, Ilkka
Vehkaoja, Antti
2018

This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1007/978-981-10-9038-7_75
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tty-201809252335

Kuvaus

Peer reviewed
Tiivistelmä
<p>Atrial fibrillation (AF) can be detected by analysis of the rhythm of heartbeats. The development of photoplethysmography (PPG) technology has enabled comfortable and unobtrusive physiological monitoring of heart rate with a wrist-worn device. Therefore, it is important to examine the possibility of using PPG signal to detect AF episodes in real-world situations. The aim of this paper is to evaluate an AF detection method based on artificial neural networks (ANN) from PPG-derived beat-to-beat interval data used for primary screening or monitoring purposes. The proposed classifier is able to distinguish between AF and sinus rhythms (SR). In total 30 patients (15 with AF, 15 with SR, mean age 71.5 years) with multiple comorbidities were monitored during routine postoperative treatment. The monitoring included standard ECG and a wrist-worn PPG monitor with green and infrared light sources. The input features of the ANN are based on the information obtained from inter-beat interval (IBI) sequences of 30 consecutive PPG pulses. One of the main concerns about the PPG signals is their susceptibility to be corrupted by noise and artifacts mostly caused by subject movement. Therefore, in the proposed method the IBI reliability is automatically evaluated beforehand. The amount of uncertainty due to unreliable beats was 15.42%. The achieved sensitivity and specificity of AF detection for 30 beats sequences were 99.20 ± 1.3 and 99.54 ± 0.64, respectively. Based on these results, the ANN algorithm demonstrated excellent performance at recognizing AF from SR using wrist PPG data.</p>
Kokoelmat
  • TUNICRIS-julkaisut [24682]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste