Revisited Perturbation Frequency Design Guideline for Direct Fixed-Step Maximum Power Point Tracking Algorithms

Kivimäki, Jyri; Kolesnik, Sergei; Sitbon, Moshe; Suntio, Teuvo; Kuperman, Alon (2017-06)

 
Avaa tiedosto
Revisited_Perturbation_Frequency_Design_Guideline_for_Direct_Fixed_Step_Maximum_Power_Point_Tracking_Algorithms.pdf (649.3Kt)
Lataukset: 



Kivimäki, Jyri
Kolesnik, Sergei
Sitbon, Moshe
Suntio, Teuvo
Kuperman, Alon
06 / 2017

IEEE Transactions on Industrial Electronics
This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1109/TIE.2017.2674589
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tty-201802141234

Kuvaus

Peer reviewed
Tiivistelmä
<p>In order to optimize the performance of direct (or perturbative) fixed-step maximum power point tracking algorithms (e.g., perturb and observe and incremental conductance), two design parameters-perturbation frequency and step size-must be selected. The main requirement for perturbation frequency design is ensuring the period between two successive perturbations is longer than settling time of photovoltaic generator power transient. According to existing design guidelines, perturbation frequency should be selected at maximum power point, corresponding to standard test conditions. However, due to finite resolution of digital controllers, maximum power region rather than single maximum power point exists in practice. Therefore, operating point can arbitrarily reside within this region, belonging either to constant-current or constant-voltage I-V curve parts. It is shown that the photovoltaic generator power transient settling process is significantly slower in constant current than maximum power region due to increased value of dynamic resistance. Consequently, perturbation frequency design should be carried out in constant-current region rather than at maximum power point. Short-circuit condition should be selected as worst-case design operation point, where photovoltaic generator dynamic resistance obtains highest value. Then, perturbation frequency design becomes photovoltaic generator independent, influenced only by interfacing converter component values. Experimental results validate presented findings successfully.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20247]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste