Determining maximum MPP-tracking sampling frequency for input-voltage-controlled PV-interfacing converter

Kivimäki, Jyri; Sitbon, Moshe; Kolesnik, Sergei; Kuperman, Alon; Suntio, Teuvo (2017-02-13)

 
Avaa tiedosto
PID4335701.pdf (969.4Kt)
Lataukset: 



Kivimäki, Jyri
Sitbon, Moshe
Kolesnik, Sergei
Kuperman, Alon
Suntio, Teuvo
13.02.2017

This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1109/ECCE.2016.7855036
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tty-201802141221

Kuvaus

Peer reviewed
Tiivistelmä
<p>A maximum-power-point tracking (MPPT) algorithm is essential in all controllers of solar power electronic converters due to the nonlinear current-voltage characteristics of a photovoltaic generator. One of the most widely utilized algorithms are perturbative MPPT techniques such as perturb and observe and incremental conductance methods due to their simple implementation with relatively good tracking performance. However, in order to optimize the performance of such algorithms, the design parameters - sampling frequency and perturbation step size - need to be designed in respect to interfaced power electronic converter. Recent studies have provided state-of-art MPP-tracking design rules for single and two-stage grid-connected PV systems. Unfortunately, the analysis of those studies does not provide analytical results for PV power transient response under feedback-controlled converters. This paper provides reduced-order transfer functions for the converters equipped with either I-type or PID-type controllers in order to approximate the maximum sampling or perturbation frequency for MPP-tracking algorithms. The analysis reveals the factors affecting the transient behavior similarly as in open-loop converter providing valuable tools for optimizing MPP-tracking perturbation frequency design.</p>
Kokoelmat
  • TUNICRIS-julkaisut [23480]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste