Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Environmental noise monitoring using source classification in sensors

Maijala, Panu; Shuyang, Zhao; Heittola, Toni; Virtanen, Tuomas (2017-08-12)

 
Avaa tiedosto
Environmental_noise_monitoring_using_source_classification_in_sensors.pdf (1.989Mt)
Lataukset: 



Maijala, Panu
Shuyang, Zhao
Heittola, Toni
Virtanen, Tuomas
12.08.2017

Applied Acoustics
doi:10.1016/j.apacoust.2017.08.006
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tty-201710041981

Kuvaus

Peer reviewed
Tiivistelmä
<p>Environmental noise monitoring systems continuously measure sound levels without assigning these measurements to different noise sources in the acoustic scenes, therefore incapable of identifying the main noise source. In this paper a feasibility study is presented on a new monitoring concept in which an acoustic pattern classification algorithm running in a wireless sensor is used to automatically assign the measured sound level to different noise sources. A supervised noise source classifier is learned from a small amount of manually annotated recordings and the learned classifier is used to automatically detect the activity of target noise source in the presence of interfering noise sources. The sensor is based on an inexpensive credit-card-sized single-board computer with a microphone and associated electronics and wireless connectivity. The measurement results and the noise source information are transferred from the sensors scattered around the measurement site to a cloud service and a noise portal is used to visualise the measurements to users. The proposed noise monitoring concept was piloted on a rock crushing site. The system ran reliably over 50 days on site, during which it was able to recognise more than 90% of the noise sources correctly. The pilot study shows that the proposed noise monitoring system can reduce the amount of required human validation of the sound level measurements when the target noise source is clearly defined.</p>
Kokoelmat
  • TUNICRIS-julkaisut [24210]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste