Hyppää sisältöön
    • Suomeksi
    • In English
Trepo
  • Suomeksi
  • In English
  • Kirjaudu
Näytä viite 
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
  •   Etusivu
  • Trepo
  • TUNICRIS-julkaisut
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Inhaled corticosteroid delivery is markedly affected by breathing pattern and valved holding chamber model

Ojanperä, Laura; Lehtimäki, Lauri; Huhtala, Heini; Csonka, Péter (2024)

 
Avaa tiedosto
Pediatric_Pulmonology_-_2024_-_Ojanper_-_Inhaled_corticosteroid_delivery_is_markedly_affected_by_breathing_pattern_and.pdf (1.241Mt)
Lataukset: 



Ojanperä, Laura
Lehtimäki, Lauri
Huhtala, Heini
Csonka, Péter
2024

Pediatric Pulmonology
doi:10.1002/ppul.27300
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202410169302

Kuvaus

Peer reviewed
Tiivistelmä
<p>Background: There is a scarcity of high-quality research on the efficient delivery of inhaled corticosteroids using valved holding chambers (VHCs) in children. Methods: The delivered dose (DD) of fluticasone from a metered dose inhaler (pMDI) was tested using four VHCs: AeroChamber plus Flow-Vu (AC), Babyhaler (BH), EasyChamber (EC), and Optichamber Diamond (OD). The in vitro setup included an anatomical child throat model, Next Generation Impactor, and a breathing simulator to generate tidal breathing of a four and a 6-year-old child, and adult type single inhalation. Results: OD showed the lowest proportion of fluticasone trapped in the throat with all breathing patterns. AC showed similar fine particle dose (FPD) in the respirable range (1–5 µm) irrespective of the breathing pattern. For BH, the median FPD 1–5 µm was highest during adult breathing. OD and EC showed higher overall DD and higher doses in the 1–5 µm range with paediatric breathing profiles compared to adult inhalation. The median DD and FPD 1–5 µm were significantly lower with BH compared to any other VHCs during tidal breathing. Compared to EC, the FPD of the other VHCs were skewed towards <2 µm particles. Conclusion: Fluticasone delivery is markedly affected by breathing pattern and VHC model. The observed differences in throat deposition and FPD delivered may have significant clinical implications for side effects and controlling airway inflammation. All VHCs intended for paediatric use should undergo testing using internationally recognised standardised methods incorporating clinically relevant paediatric breathing patterns.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20161]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste