Dosimetric consequences of adapting the craniocaudal isocenter distance to daily patient position in craniospinal irradiation using volumetric modulated arc therapy

Heikkilä, Annele; Vanhanen, Antti; Rossi, Maija; Koivumäki, Tuomas; Postema, Michiel; Boman, Eeva (2024-01-09)

 
Avaa tiedosto
J_Applied_Clin_Med_Phys_-_2024_-_Heikkil_C3_A4_-_Dosimetric_consequences_of_adapting_the_craniocaudal_isocenter_distance_to.pdf (1.655Mt)
Lataukset: 



Heikkilä, Annele
Vanhanen, Antti
Rossi, Maija
Koivumäki, Tuomas
Postema, Michiel
Boman, Eeva
09.01.2024

Journal of Applied Clinical Medical Physics
e14530
doi:10.1002/acm2.14530
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202410309675

Kuvaus

Peer reviewed
Tiivistelmä
PURPOSE: In craniospinal irradiation, two or three isocenter groups along the craniocaudal axis are required to cover the long treatment target. Adapting the isocenter distance according to daily deviations in patient position is challenging because dosimetric hot or cold spots may occur in the field junction. The aim of this study was to quantify the effect of adapting the isocenter distance to patient position on the dose distribution of the field overlap region in craniospinal irradiation using partial-arc volumetric modulated arc therapy. METHODS: The magnitude of isocenter distance deviations in craniocaudal direction was quantified by registering the setup images of 204 fractions of 12 patients to the planning images. The dosimetric effect of these deviations was determined by shifting the isocenters of the original treatment plan and calculating the resulting dose distribution. RESULTS: On fraction-level, deviations larger than 3 mm caused more than 5 percentage point changes in the doses covering 2% (D2%) and 98% (D98%) of the junction volume in several patients. On treatment course-level, the changes in D2% and D98% of the junction volume were less than 5 percentage points in all cases except for one patient. CONCLUSIONS: Craniocaudal isocenter distance adaptation can be conducted provided that the mean isocenter distance deviation over the treatment course is within 3 mm.
Kokoelmat
  • TUNICRIS-julkaisut [22195]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste