Comparison of X-Ray Absorption in Mandibular Tissues and Tissue-Equivalent Polymeric Materials Using PHITS Monte Carlo Simulations

Gokcekuyu, Yasemin; Ekinci, Fatih; Buyuksungur, Arda; Guzel, Mehmet Serdar; Acici, Koray; Asuroglu, Tunc (2024-11)

 
Avaa tiedosto
applsci-14-10879-v3.pdf (4.884Mt)
Lataukset: 



Gokcekuyu, Yasemin
Ekinci, Fatih
Buyuksungur, Arda
Guzel, Mehmet Serdar
Acici, Koray
Asuroglu, Tunc
11 / 2024

Applied Sciences (Switzerland)
10879
doi:10.3390/app142310879
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202501021047

Kuvaus

Peer reviewed
Tiivistelmä
This study investigates the absorption of X-rays in mandibular tissues by comparing real tissues with tissue-equivalent materials using the PHITS Monte Carlo simulation program. The simulation was conducted over a range of X-ray photon energies from 50 to 100 keV, with increments of 5 keV, to evaluate the dose absorbed by different tissues. Real tissues, such as the skin, parotid gland, and masseter muscle, were compared with their tissue-equivalent polymeric materials, including PMMA, Parylene N, and Teflon. The results showed that the real tissues generally absorbed more X-rays than their corresponding equivalents, especially at lower energy levels. For instance, at 50 keV, differences in the absorbed doses reached up to 50% for the masseter muscle and its equivalent, while this gap narrowed at higher energies. The study highlights the limitations of current tissue-equivalent materials in accurately simulating real tissue behavior, particularly in low-energy X-ray applications. These discrepancies suggest that utilizing tissue-equivalent materials may lead to less accurate medical imaging and radiotherapy dose calculations. Future research should focus on improving tissue-equivalent materials and validating simulation results with experimental data to ensure more reliable dosimetric outcomes. This study provides a foundation for refining radiation dose calculations and improving patient safety in clinical applications involving X-rays.
Kokoelmat
  • TUNICRIS-julkaisut [20711]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste