Wearable EEG-Based Depth of Anesthesia Monitoring: A Non- Parametric Feature Set

Shahbakhti, Mohammad; Krycinska, Roza; Beiramvand, Matin; Hakimi, Naser; Lipping, Tarmo; Chen, Wei; Broniec-Wojcik, Anna; Augustyniak, Piotr; Tanaka, Toshihisa; Sole-Casals, Jordi; Wierzchon, Michal; Wordliczek, Jerzy (2024)

 
Avaa tiedosto
Wearable_EEG-Based_Depth_of_Anesthesia_Monitoring_A_Nonparametric_Feature_Set.pdf (8.971Mt)
Lataukset: 



Shahbakhti, Mohammad
Krycinska, Roza
Beiramvand, Matin
Hakimi, Naser
Lipping, Tarmo
Chen, Wei
Broniec-Wojcik, Anna
Augustyniak, Piotr
Tanaka, Toshihisa
Sole-Casals, Jordi
Wierzchon, Michal
Wordliczek, Jerzy
2024

IEEE Sensors Journal
This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
doi:10.1109/JSEN.2024.3390604
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202409208818

Kuvaus

Peer reviewed
Tiivistelmä
<p>Objectives: Commercial systems for monitoring the depth of anesthesia (DoA) are often financially inaccessible to developing countries. As an alternative, a wearable single frontal electroencephalogram (EEG) device can be utilized. Nonetheless, most studies addressing DoA monitoring utilizing just one frontal EEG channel rely on nonlinear features that require parameter tuning before computation, overlooking the potential interchangeability of such features across different databases. Methods: Here, we present a parameter-free feature set for DoA monitoring using a single frontal EEG channel and evaluate its performance on two databases with different characteristics. First, the EEG signal is de-noised and split into its sub-bands. Second, several parameter-free features based on entropy, power and frequency, fractal, and variation are extracted from all sub-bands. Finally, the distinguished features are chosen and input into a random forest regressor to estimate the DoA index values. Results: The reliability of the proposed feature set for the DoA monitoring is indicated by achieving a comparable correlation coefficient of 0.80 and 0.79 and mean absolute error of 7.1 and 9.0 between the reference and estimated DoA index values for Databases I and II, respectively. Significance: The obtained results from this study confirm the possibility of affordable DoA monitoring using a portable EEG system. Given its simplicity and comparable results for both databases, the proposed feature set holds promise for practical application in real-world scenarios.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20709]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste