Simulation-based feasibility study of monitoring of intracerebral hemorrhages and detection of secondary hemorrhages using electrical impedance tomography

Toivanen, Jussi; Paldanius, Antti; Dekdouk, Bachir; Candiani, Valentina; Hänninen, Asko; Savolainen, Tuomo; Strbian, Daniel; Forss, Nina; Hyvönen, Nuutti; Hyttinen, Jari; Kolehmainen, Ville (2024-01)

 
Avaa tiedosto
014502_1.pdf (7.198Mt)
Lataukset: 



Toivanen, Jussi
Paldanius, Antti
Dekdouk, Bachir
Candiani, Valentina
Hänninen, Asko
Savolainen, Tuomo
Strbian, Daniel
Forss, Nina
Hyvönen, Nuutti
Hyttinen, Jari
Kolehmainen, Ville
01 / 2024

Journal of Medical Imaging
014502
doi:10.1117/1.JMI.11.1.014502
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202404113468

Kuvaus

Peer reviewed
Tiivistelmä
Purpose: We present a simulation-based feasibility study of electrical impedance tomography (EIT) for continuous bedside monitoring of intracerebral hemorrhages (ICH) and detection of secondary hemorrhages. Approach: We simulated EIT measurements for six different hemorrhage sizes at two different hemorrhage locations using an anatomically detailed computational head model. Using this dataset, we test the ICH monitoring and detection performance of our tailor-made, patient-specific stroke-monitoring algorithm that utilizes a novel combination of nonlinear region-of-interest difference imaging, parallel level sets regularization and a prior-conditioned least squares algorithm. We compare the results of our algorithm to the results of two reference algorithms, a total variation regularized absolute imaging algorithm and a linear difference imaging algorithm. Results: The tailor-made stroke-monitoring algorithm is capable of indicating smaller changes in the simulated hemorrhages than either of the reference algorithms, indicating better monitoring and detection performance. Conclusions: Our simulation results from the anatomically detailed head model indicate that EIT equipped with a patient-specific stroke-monitoring algorithm is a promising technology for the unmet clinical need of having a technology for continuous bedside monitoring of brain status of acute stroke patients.
Kokoelmat
  • TUNICRIS-julkaisut [22389]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste