Surface alterations and compound release from aligner attachments in vitro
Iliadi, Anna; Zervou, Sevasti Kiriaki; Koletsi, Despina; Schätzle, Marc; Hiskia, Anastasia; Eliades, Theodore; Eliades, George (2024-08)
Iliadi, Anna
Zervou, Sevasti Kiriaki
Koletsi, Despina
Schätzle, Marc
Hiskia, Anastasia
Eliades, Theodore
Eliades, George
08 / 2024
European Journal of Orthodontics
cjae026
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202408128044
https://urn.fi/URN:NBN:fi:tuni-202408128044
Kuvaus
Peer reviewed
Tiivistelmä
Aim: The aim of the present study was to assess the alterations in morphology, roughness, and composition of the surfaces of a conventional and a flowable composite attachment engaged with aligners, and to evaluate the release of resin monomers and their derivatives in an aqueous environment. Methods: Zirconia tooth-arch frames (n=20) and corresponding thermoformed PET-G aligners with bonded attachments comprising two composite materials (universal - C and flowable - F) were fabricated. The morphological features (stereomicroscopy), roughness (optical profilometry), and surface composition (ATR-FTIR) of the attachments were examined before and after immersion in water. To simulate intraoral use, the aligners were removed and re-seated to the frames four times per day for a 7-day immersion period. After testing, the eluents were analyzed by LC-MS/MS targeting the compounds Bis-GMA, UDMA, 2-HEMA, TEGDMA and BPA and by LC-HRMS for suspect screening of the leached dental material compounds and their degradation products. Results: After testing, abrasion-induced defects were found on attachment surfaces such as scratches, marginal cracks, loss of surface texturing, and fractures. The morphological changes and debonding rate were greater in F. Comparisons (before-after testing) revealed a significantly lower Sc roughness parameter in F. The surface composition of the aligners after testing showed minor changes from the control, with insignificant differences in the degree of C=C conversion, except for few cases with strong evidence of hydrolytic degradation. Targeted analysis results revealed a significant difference in the compounds released between Days 1 and 7 in both materials. Insignificant differences were found when C was compared with F in both timeframes. Several degradation products were detected on Day 7, with a strong reduction in the concentration of the targeted compounds. Conclusions: The use of aligners affects the surface characteristics and degradation rate of composite attachments in an aqueous environment, releasing monomers, and monomer hydrolysates within 1-week simulated use.
Kokoelmat
- TUNICRIS-julkaisut [24163]