Demand Response with Electrical Heating in Detached Houses in Finland and Comparison with BESS for Increasing PV Self-Consumption

Koskela, Juha; Järventausta, Pertti (2023-01)

 
Avaa tiedosto
energies_16_00497.pdf (11.84Mt)
Lataukset: 



Koskela, Juha
Järventausta, Pertti
01 / 2023

Energies
497
doi:10.3390/en16010497
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202301241675

Kuvaus

Peer reviewed
Tiivistelmä
<p>Distributed electric power production by small-scale customers is increasing continuously. Photovoltaic production is a popular method of producing self-energy for customers. Additionally, power systems require more flexibility when weather-dependent renewable energy production increases. Small-scale customers can increase the self-consumption of self-produced energy by using batteries or a demand response operation. However, batteries require high investment, and demand response operations induce a loss of comfort. Customers who heat their buildings using electric heaters are a good target for demand response operations because their heating can be controlled with limited changes in the indoor temperature. The demand response potential of a building can be defined by simply using customer load profiles and knowledge of the outdoor temperature. Any other information is not required in the proposed novel method. A tolerable variation in indoor temperature corresponds to considerably smaller battery capacity, though it is still a significant amount. With an optimally sized photovoltaic system, it is possible to use both methods simultaneously to increase self-consumption. Maximal benefits can be attained from both methods if the battery system is used as a primary control and the demand response is used as a secondary control. The defined novel method for determining the demand response potential of small-scale customers can also be used when estimating the flexibility of a large customer group. Small-scale customers together can provide significant flexible capacity when their electrical heating is centrally controlled.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20711]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste