Motion-Based Extrinsic Sensor-to-Sensor Calibration: Effect of Reference Frame Selection for New and Existing Methods

Välimäki, Tuomas; Garigipati, Bharath; Ghabcheloo, Reza (2023-04)

 
Avaa tiedosto
Motion_Based_Extrinsic_Sensor.pdf (544.0Kt)
Lataukset: 



Välimäki, Tuomas
Garigipati, Bharath
Ghabcheloo, Reza
04 / 2023

Sensors
3740
doi:10.3390/s23073740
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202305024919

Kuvaus

Peer reviewed
Tiivistelmä
This paper studies the effect of reference frame selection in sensor-to-sensor extrinsic calibration when formulated as a motion-based hand–eye calibration problem. As the sensor trajectories typically contain some composition of noise, the aim is to determine which selection strategies work best under which noise conditions. Different reference selection options are tested under varying noise conditions in simulations, and the findings are validated with real data from the KITTI dataset. The study is conducted for four state-of-the-art methods, as well as two proposed cost functions for nonlinear optimization. One of the proposed cost functions incorporates outlier rejection to improve calibration performance and was shown to significantly improve performance in the presence of outliers, and either match or outperform the other algorithms in other noise conditions. However, the performance gain from reference frame selection was deemed larger than that from algorithm selection. In addition, we show that with realistic noise, the reference frame selection method commonly used in the literature, is inferior to other tested options, and that relative error metrics are not reliable for telling which method achieves best calibration performance.
Kokoelmat
  • TUNICRIS-julkaisut [22384]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste