Lung-depositing surface area (LDSA) of particles in office spaces around Europe: Size distributions, I/O-ratios and infiltration

Silvonen, Ville; Salo, Laura; Raunima, Tuomas; Vojtisek-Lom, Michal; Ondracek, Jakub; Topinka, Jan; Schins, Roel P.F.; Lepistö, Teemu; Lintusaari, Henna; Saarikoski, Sanna; Barreira, Luis M.F.; Hoivala, Jussi; Markkula, Lassi; Kulmala, Ilpo; Vinha, Juha; Karjalainen, Panu; Rönkkö, Topi (2023-12-01)

 
Avaa tiedosto
1-s2.0-S0360132323010260-main.pdf (7.381Mt)
Lataukset: 



Silvonen, Ville
Salo, Laura
Raunima, Tuomas
Vojtisek-Lom, Michal
Ondracek, Jakub
Topinka, Jan
Schins, Roel P.F.
Lepistö, Teemu
Lintusaari, Henna
Saarikoski, Sanna
Barreira, Luis M.F.
Hoivala, Jussi
Markkula, Lassi
Kulmala, Ilpo
Vinha, Juha
Karjalainen, Panu
Rönkkö, Topi
01.12.2023

Building and Environment
110999
doi:10.1016/j.buildenv.2023.110999
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-2023111510014

Kuvaus

Peer reviewed
Tiivistelmä
Air pollution, and specifically particulate matter pollution, is one of the greatest dangers to human health. Outdoor air pollution ranks third in causes for premature death. Improving indoor air quality is of immense importance, as the time spent indoors is often much greater than the time spent outdoors. In this experimental study, we evaluate the levels of particle pollution in indoor air in four offices across Europe, compare the indoor particles to outdoor particles and assess where the particles originate from. The measurements were conducted with an Electrical Low-Pressure Impactor (ELPI+) for particles between 6 nm and 1 μm. The chosen metric, lung-deposited particle surface area (LDSA), targets the health impacts of particle pollution. Based on the measurements, we determined that most of the indoor air particles infiltrated from outdoor air, although two of the offices had very limited indoor activity during the measurement campaigns and may not represent typical use. The highest median indoor LDSA concentration during daytime hours was 27.2 μm2/cm3, whereas the lowest was 2.8 μm2/cm3. Indoor air in general had lower LDSA concentrations than outdoor air, the corresponding outdoor LDSA concentrations being 35.8 μm2/cm3 and 9.8 μm2/cm3. The particle size ranges which contributed to the highest concentrations were 50–100 nm and 300–500 nm. These size ranges correspond to soot mode and accumulation mode particles, which represent local and regional sources, respectively. Based on this study, limiting particle infiltration is the key factor in keeping indoor air in offices free of lung-depositing particles.
Kokoelmat
  • TUNICRIS-julkaisut [24988]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste