Ultra-low-dose computed tomography and chest X-ray in follow-up of high-grade soft tissue sarcoma: a prospective comparative study

Salminen, Samuli; Jäämaa, Sari; Nevala, Riikka; Sormaala, Markus J.; Koivikko, Mika; Tukiainen, Erkki; Repo, Jussi; Blomqvist, Carl; Sampo, Mika (2024-12)

 
Avaa tiedosto
s41598-024-57770-z.pdf (1.226Mt)
Lataukset: 



Salminen, Samuli
Jäämaa, Sari
Nevala, Riikka
Sormaala, Markus J.
Koivikko, Mika
Tukiainen, Erkki
Repo, Jussi
Blomqvist, Carl
Sampo, Mika
12 / 2024

Scientific Reports
7181
doi:10.1038/s41598-024-57770-z
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tuni-202404103427

Kuvaus

Peer reviewed
Tiivistelmä
<p>Ultra-low-dose computed tomography (ULD-CT) may combine the high sensitivity of conventional computed tomography (CT) in detecting sarcoma pulmonary metastasis, with a radiation dose in the same magnitude as chest X-ray (CXR). Fifty patients with non-metastatic high-grade soft tissue sarcoma treated with curative intention were recruited. Their follow-up involved both CXR and ULD-CT to evaluate their different sensitivity. Suspected findings were confirmed by conventional CT if necessary. Patients with isolated pulmonary metastases were treated with surgery or stereotactic body radiation therapy (SBRT) with curative intent if possible. The median effective dose from a single ULD-CT study was 0.27 mSv (range 0.12 to 0.89 mSv). Nine patients were diagnosed with asymptomatic lung metastases during the follow-up. Only three of them were visible in CXR and all nine in ULD-CT. CXR had therefore only a 33% sensitivity compared to ULD-CT. Four patients were operated, and one had SBRT to all pulmonary lesions. Eight of them, however, died of the disease. Two patients developed symptomatic metastatic recurrence involving extrapulmonary sites+/−the lungs between two imaging rounds. ULD-CT has higher sensitivity for the detection of sarcoma pulmonary metastasis than CXR, with a radiation dose considerably lower than conventional CT. Clinical trial registration: NCT05813808. 04-14-2023.</p>
Kokoelmat
  • TUNICRIS-julkaisut [20143]
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste
 

 

Selaa kokoelmaa

TekijätNimekkeetTiedekunta (2019 -)Tiedekunta (- 2018)Tutkinto-ohjelmat ja opintosuunnatAvainsanatJulkaisuajatKokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
Kalevantie 5
PL 617
33014 Tampereen yliopisto
oa[@]tuni.fi | Tietosuoja | Saavutettavuusseloste