Modeling of load-transient response of direct-duty-ratio-controlled buck converter
Suntio, Teuvo; Kivimäki, Jyri (2017-11-09)
Suntio, Teuvo
Kivimäki, Jyri
IEEE
09.11.2017
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:tty-201801041022
https://urn.fi/URN:NBN:fi:tty-201801041022
Kuvaus
Peer reviewed
Tiivistelmä
This paper provides a simple analytical model for the closed-loop output impedance of a direct-duty-ratio-controlled buck converter, which can be used to predict the behavior of the output voltage during a load-current transient. The modeling method utilizes standard control theory to obtain the model for the sensitivity function based on the crossover frequency and phase margin of the output-voltage feedback loop as well as on a clever estimate for the corresponding open-loop output impedance. The modeling method is validated by means of simulations and experimental tests.